RI=0, CMPE=0, FSAMP=00, DFDIS=0, RIE=0, RN=0
Voltage Monitor 1 Circuit Control Register 0
RIE | Voltage Monitor 1 Interrupt/Reset Enable 0 (0): Disable 1 (1): Enable |
DFDIS | Voltage monitor 1 Digital Filter Disabled Mode Select 0 (0): Enable the digital filter 1 (1): Disable the digital filter |
CMPE | Voltage Monitor 1 Circuit Comparison Result Output Enable 0 (0): Disable voltage monitor 1 circuit comparison result output 1 (1): Enable voltage monitor 1 circuit comparison result output |
FSAMP | Sampling Clock Select 0 (00): 1/2 LOCO frequency 1 (01): 1/4 LOCO frequency 2 (10): 1/8 LOCO frequency 3 (11): 1/16 LOCO frequency |
RI | Voltage Monitor 1 Circuit Mode Select 0 (0): Generate voltage monitor 1 interrupt on Vdet1 crossing 1 (1): Enable voltage monitor 1 reset when the voltage falls to and below Vdet1 |
RN | Voltage Monitor 1 Reset Negate Select 0 (0): Negate after a stabilization time (tLVD1) when VCC > Vdet1 is detected 1 (1): Negate after a stabilization time (tLVD1) on assertion of the LVD1 reset |